Geberit Mapress Copper T-Pieces For Inlet And Return Flow

Loading...
Useful Information

Technical Specification

  • Operating Temperature: 0-100°C (For cold and hot potable water)
  • Maximum Operating Pressure: 16 bar/ 1600kPa (For cold and hot potable water)
  • Material: Non-alloy steel 1.0034 E195 (EN 10305), copper-plated exterior
  • Seal Ring: CIIR black seal ring
  • Connection Technology: Press-fit with leak detection and pressing indicator
  • Applications: Suitable for heating and cooling systems with and without antifreeze agents, including skirting board heating systems
  • Installation: Suitable for both surface-mounted and concealed installations

Description

The Geberit Mapress Copper T-Pieces for Inlet and Return Flow are specifically designed for heating and cooling systems, including skirting board heating installations. These T-pieces allow for efficient connection of pipes to manage both inlet and return flow in systems that either contain or exclude antifreeze agents. With advanced press-fit technology, these fittings provide a secure, leak-proof connection, making them ideal for installations that require reliability and long-term performance.

Key Features

  • Specialised for Heating and Cooling: Exclusively designed for heating and cooling applications, these T-pieces are perfect for managing both inlet and return flow in water-based systems, whether with or without antifreeze agents.
  • Inlet and Return Flow Flexibility: The inlet and return flow connections are interchangeable, offering greater flexibility in system design and simplifying installation in heating and cooling circuits.
  • Non-Alloy Steel Construction: Made from high-quality non-alloy steel (1.0034 E195 EN 10305), these T-pieces offer excellent durability and corrosion resistance, ensuring long-lasting performance in both heating and cooling applications.
  • Press-Fit Technology: The press-fit system eliminates the need for welding or soldering, providing a faster, safer, and fire-free installation. This reduces labour time and enhances overall installation safety, particularly in residential environments.
  • Leak Detection: The T-pieces are designed to be leaky if unpressed, allowing installers to easily identify any unpressed connections during installation, ensuring a secure and reliable system.
  • Reliable Sealing: Equipped with CIIR black seal rings, these fittings ensure a dependable, leak-proof connection that can withstand the demands of high-pressure and high-temperature heating and cooling systems.
  • Copper-Plated Exterior: The T-pieces feature an outside copper-plated finish, which adds an extra layer of protection and compatibility with copper pipe systems.
  • Protected Installation: The pressing sockets come with transparent protection plugs to keep seal rings free from dirt and debris during installation, ensuring a clean and hygienic connection.
  • Clear Identification: With pressing indicators and colour-coded components, the T-pieces allow for easy identification during installation, reducing the chance of errors and confusion with third-party products.
SKUArt. no.DNd, ø (mm)d1, ø (mm)arc (degrees)AD (cm)L (cm)L1 (cm)l1 (cm)Z (cm)
24005121515904–62.710.86.510
2400615 / 121815904–62.9116.510
2400720 / 122215904–63.311.26.510
Application Purposes Operating Temperature Maximum Operating Pressure
Liquid Media
For cold and hot potable water 0°C to 100 °C 16 bar / 1600 kPa (5)
For cooling and heating water without antifreeze agent 0°C to 100 °C 16 bar / 1600 kPa (4)
For cooling and heating water with antifreeze agent -30 to +120 °C 16 bar / 1600 kPa (4)
For district heating water ≤ 120 °C 0°C to 120 °C 16 bar / 1600 kPa (4) (9)
For service water and process water  0°C to 120 °C 16 bar / 1600 kPa (7)
Gaseous Media
For compressed air (purity class oil 2-3) (1) 0°C to 100 °C 12 bar / 1200 kPa (6)
For compressed air (purity class oil 0-X) (1) 0°C to 100 °C 12 bar / 1200 kPa (6)
For negative pressure (2) 0°C to 100 °C Abs. ≥ 0,2 bar/20 kPa
For inert gases (e.g. nitrogen) 0°C to 100 °C 12 bar / 1200 kPa (6)
For natural gases -20 to +70 °C MOP 5 / GT 1
For liquefied gases -20 to +70 °C MOP 5 / GT 1
  1. Usable negative pressure for Geberit piping systems:
    • The usable negative pressure results from the air pressure at the installation site minus the absolute pressure of 200 mbar. Example: 980 mbar air pressure - 200 mbar absolute pressure = 780 mbar usable negative pressure in the piping system.
  2. Usable negative pressure for Geberit piping systems:
    • The usable negative pressure is calculated on the basis of the air pressure at the place of installation minus the absolute pressure of 200 mbar. Example: 980 mbar air pressure - 200 mbar absolute pressure = 780 mbar usable negative pressure in the piping system.
  3. Lifetime with collector standstill: 200 h/a at 180 °C; 60 h/a at 200 °C; total 500 h/lifetime at 220 °C
  4. Use of inhibitors, corrosion-protection agents, antifreeze agents only after approval by Geberit
  5. 10 bar / 1000 kPa for MasterFix and MeplaFix
  6. Approved up to d54 mm
  7. Following Geberit approval
  8. Oil purity class in accordance with ISO 8573-1:2010E; for details on moisture and particles, see technical information "Geberit Piping Systems for Compressed Air Installations" 
  9. Not for fittings with EPDM, black seal rings

IMPORTANT: The technical data given on this website is for preliminary information purposes only and is published without guarantee. All line drawings are for illustrative purposes only and should not be regarded as wholly accurate in every detail. We reserve the right to withdraw or to alter the specification of any product without notice. For more information, please consult our Terms of Business.

If you require any further information, our excellent customer service team is here to help so please call us on 01794 835835.

 

Grouped product items
Code Product Name List Price You Save You Pay
No options of this product are available.