Aluminium Pipe

Key Features / Tech Specs:

  • PPS line: 100% aluminium pipe
  • Compact, lightweight and durable
  • Maximum pressure of 16 bar
  • A leak free system with optimised flow rates
  • A clean, high quality air supply

 

An Open System:

Pressure: 8 bar | Max. Pressure drop: 5% (0.4 bar) | Max. Speed 10m/s

Compressor

Length of main line

 Power

Flow Rate 

 50m

100m

150m

300m

500m

750m

1000m

1300m

1600m

kW

HP

Nm3/h

NI/min

Scfm

164ft

328ft

492ft

984ft

1640ft

2460ft

3280ft

4265ft

5249ft

2.2 

  3

22 

 367

13

16 

 16

 20

 20

25 

 25

25 

 25

32 

3

4

30

500

18

16

20

20

25

25

25

32

32

32

4

5.5

40

667

24

20

20

25

25

32

32

32

32

32

5.5

7.5

50

834

29

20

25

25

25

32

32

32

40

40

7.5

10

70

1167

41

20

25

25

32

32

40

40

40

40

11

15

100

1667

59

25

32

32

32

40

40

40

50

50

15

20

150

2500

88

32

32

32

40

50

50

50

50

63

18

25

180

3000

106

32

32

40

40

50

50

50

63

63

22

30

220

3667

129

40

40

40

50

50

50

63

63

63

26

35

260

4334

153

40

40

40

50

50

63

63

63

63

30

40

300

5000

176

40

40

50

50

63

63

63

63

80

37

50

370

6167

218

50

50

50

50

63

63

63

80

80

45

60

450

7500

265

50

50

50

63

63

80

80

80

80

55

75

550

9167

324

63

63

63

63

80

80

80

80

100

75

100

750

12500

441

63

63

63

80

80

80

100

100

100

90

120

900

15000

529

80

80

80

80

80

100

100

100

100

110

150

1100

18334

647

80

80

80

80

100

100

100

100

 

130

175

1300

21667

765

80

80

80

80

100

100

100

 

 

160

215

1600

26667

941

100

100

100

100

100

 

 

 

 

200

270

2000

33334

1176

100

100

100

100

 

 

 

 

 

A Closed System:

Pressure: 8 bar | Max. Pressure drop: 5% (0.4 bar) | Max. Speed 10m/s

Compressor

Length of main line

 Power

Flow Rate 

 50m

100m

150m

300m

500m

750m

1000m

1300m

1600m

kW

HP

Nm3/h

NI/min

Scfm

164ft

328ft

492ft

984ft

1640ft

2460ft

3280ft

4265ft

5249ft

2.2

3

22

367

13

16

16

16

16

20

20

20

20

25

3

4

30

500

18

16

16

16

20

20

20

25

25

25

4

5.5

40

667

24

16

16

20

20

25

25

25

25

32

5.5

7.5

50

834

29

16

20

20

20

25

25

25

32

32

7.5

10

70

1167

41

20

20

20

25

25

32

32

32

32

11

15

100

1667

59

20

25

25

25

32

32

32

40

40

15

20

150

2500

88

25

25

32

32

32

40

40

40

40

18

25

180

3000

106

25

25

32

32

40

40

40

50

50

22

30

220

3667

129

25

32

32

40

40

40

50

50

50

26

35

260

4334

153

32

32

32

40

40

50

50

50

50

30

40

300

5000

176

32

32

40

40

50

50

50

50

63

37

50

370

6167

218

32

32

40

40

50

50

50

63

63

45

60

450

7500

265

40

40

40

50

50

63

63

63

63

55

75

550

9167

324

40

40

50

50

63

63

63

63

80

75

100

750

12500

441

50

50

50

63

63

63

80

80

80

90

120

900

15000

529

50

50

50

63

63

80

80

80

80

110

150

1100

18334

647

63

63

63

63

80

80

80

80

100

130

175

1300

21667

765

63

63

63

63

80

80

80

100

100

160

215

1600

26667

941

63

63

63

80

80

80

100

100

100

200

270

2000

33334

1176

80

80

80

80

80

100

100

100

100

250

340

2500

41667

1471

80

80

80

80

100

100

100

 

 

300

405

3000

50000

1765

100

100

100

100

100

100

 

 

 

350

475

3500

58334

2059

100

100

100

100

100

 

 

 

 

400

540

4000

66667

2353

100

100

100

100

 

 

 

 

 

Useful Info:

Pipestock are proud to supply this new cutting-edge compressed air distribution system. The aluminium Prevost Piping System was designed to be compact, light weight and durable enough to withstand the harshest operating conditions.

Please note fittings and pipe are not interchangeable with other product ranges.

Installation Instructions:

 

  • Ensure all cuts made to the pipe are straight and the inside and outside of each edge is de-burred

 

  1. The pipe must be fully inserted into the fitting – to do this, simply mark the point using the tightening key, loosen the locking nut and with one motion twist and push the pipe into the fitting – it may help if you use a lubricated spray (non aggressive)
  2. Use PTFE tape on all male threads unless a seal is supplied
  3. Make sure the pipe is straight and level, clamping every 3 metres and where it may be necessary to ensure a strong bind to the wall or ceiling of the building
  4. Tighten all fittings by hand and once the system is in place, tighten using the PPS1 CLE key and torque wrench to the following points, starting at the lower setting – for example 25mm fittings – 21-35Nm
  5. Once all fittings are tightened, set the compressor at 2 BAR and run for 5 minutes, then check each fitting for leaks, adjust if needed, and repeat the test at 8 BAR. Again check all and if the system is leak free, your customer is free to use the system

If you require any further information, our excellent customer service team is here to help so please call us on 01794 835835.